Filter Results By:

Products

Applications

Manufacturers

Current Transformers

transfers accurately proportional levels of current to multiple circuits.


Showing results: 301 - 315 of 340 items found.

  • Front End Protector

    AS-RXFEP RX - Array Solutions

    The AS-RXFEP Receiver protector limits input RF signal threshold from 1 to 150MHz to less than 0.3 Vrms to protect a receiver front end from damage due to nearby transmitted signals. The receiver still actsnormally and measured signal strength is not affected.The circuit uses a multi-stage design of transformer saturation coupling and current limiters. It also incorporates a low voltage GDT to protect from lightning events. These are for receiving only - you cannot transmit through them without damaging the unit.

  • Static Frequency Converter Systems with Built-in Isolation System

    FC3X Series - Aplab Limited

    - VFI independent output as per IEC62040- User friendly controls and indications- Compact design with inbuilt transformer- Rugged and field proven for Industrial and Defence application- Ultra light weight- Higher efficiency of operation means significantly lower running costs- State of the art IGBT based PWM technology, to increase crest factor tolerance & dynamic stability- Continuously delivers full output power at ambient as high as 45ºC- Can feed upto 400% rated current for half cycle- Very high MTBF

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

  • 1 A DIGITAL MILIOHMMETER

    MO-2Ke - MEGABRAS srl

    The MO-2Ke digital low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of contacts, switches, transformer and motor windings, etc., using test currents from 1 mA up to 1 A.It uses the Kelvin-type (4-terminals) measurement principle, thus eliminating errors caused by lead and contact resistances.Resistance readings are shown in the alphanumeric display with up to a 4 digit-resolution. It allows to measure resistances of up to 2 kO, with resolution of 0.01 mO.Measurements accuracy is guaranteed by the state-of-the-art system for signal-amplification, offset-free and with long-term stability.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Advanced Series - IBEKO Power AB

    TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.

  • Impulse Voltage And Current Testing

    Shanghai Jiuzhi Electric Co., Ltd.

    Our advanced CDY series Impulse test systems are used for impulse voltage testing of transformers, cables, gas-insulated switchgears (GIS), arresters, and other high-voltage devices. The test systems generate lightning impulse voltage (LI, 1.2/50 µs), chopping lightning impulse voltages (LIC, front time 1.2 µs, front, crest or tail chopped), and switching impulse voltage (SI, 250/2500 µs) in accordance with IEC 60060-1; as well as IEC 60076-3 for transformers, and IEC 62067, 60840 and 60502-1 for cables). By adding extra components, our impulse test system also can generate steeping wave (SWI, >2500kV/ µs) and impulse current (IC, 4/10 µs, 8/20µs, 10/350µs).

  • Enhanced SCR Power Controller

    Thyro-PX DC - Advanced Energy

    The Thyro-PX DC series shapes the future of the growing hydrogen and DC heating markets. The SCR power controller series takes advantage of the existing Thyro-PX controller card architecture and is available as three-phase units, supports up to 1800 amps DC Current, and offers superior interface options. Integrate operating modes and parameters seamlessly with the 2.8-inch, LED Thyro-Touch display and enable efficient system parameters, loading, and storage via an onboard SD-card. The Thyro-PX power controller is ideally suited for your transformer and resistive loads for glass, metal, and ceramic manufacturing. It is optimal for heating elements in electric furnaces.

  • Three Phase Power Analyzer

    Model TFT780 - Gopal Electronics

    Three Phase Power Analyzer PA700TFT is multi-range power Analyzer with basic 0.05% R+R accuracy. 8 range of voltage, 8 range of current and total 64 range of power and power factor gives more accurate result at low power factor. It has waveform mode to check the waveform of voltage and current. As well it has B/H curve mode where user can check live b/h curve of the transformer under test. The gap less four-quadrant power measurement technique gives better accuracy at distorted waveforms or AC drive (VFD) operated power supply.

  • HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY

    xPS Series - Carl E. Holmes Company

    High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)

  • Digital Insulation Testers

    The Motwane Manufacturing Company

    Motwane is India’s first company to design and develop an intelligent digital insulation tester that conducts insulation resistance tests on high voltage electrical equipment. Products like transformers, generators, motor cables, bushings, LAs, and switchgear, are prone to gradual degradation over time due to the adverse effects of temperature, humidity, and dust. The gathered test data allows clients to verify the current quality of insulation, and take appropriate action.

  • Turns Ratio Testers

    TRT Standard Series - IBEKO Power AB

    When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.

  • PC Controlled Bench Top Power Analyzer

    PA2100 - Powertek LLC

    The PA2100 is a PC controlled bench top power analyzer, allowing several electrical power measurements to be taken simultaneously during testing - from just one set of input connections. The PA2100's power measurement ability is a must in research and development, manufacturing and required for certification and traceability of manufactured goods. In addition to power measurements, apparent power (VA), harmonics, voltage, current, power factor can all be viewed and stored with ease. The PA2100 wattmeter simply connects between the ac supply and the load, various current transformer options allow measurement with any size of current from 10mA to 10000A. Typical watt meter applications include appliance testing; microwave ovens, electric stoves, heating, air conditioning, TVs, monitors, computers, electronic lighting, fans and motor controllers. Powertek wattmeters are equipped with 4mm/banana safety terminals along with optional "breakout" boxes and clamp current probes for fast and safe measurement.

  • Variable Frequency Series Resonance Test Device

    WABP - Wuhan Sangao Electrical Test Installations Limit Co.

    The device mainly AC voltage withstand test design for 10kV, 35kV, 110kV, 220kV, substation and line of all electric main equipment.Reactor with multiple separate design, Not only can meet the requirements of equipment testing conditions high voltage, small current, and can meet the requirements of low voltage AC voltage withstand test, has a wider scope of application.The device is mainly composed of variable frequency control power supply, transformer, reactor, capacitor divider.

  • Transformer Testing

    Technology Products

    The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.

  • High-Voltage Test Device

    PGK 70 HB - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 70 kV output voltage with positive or negative polarity* AC voltage testing - up to 55 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design

Get Help